Skip to content

Oxygen Panel


Back to Overhead


Oxygen Panel

Usage

CREW SUPPLY pb-sw

The CREW SUPPLY pb-sw controls oxygen supply to the masks in the cockpit.

  • ON:
  • The supply valve is open, and supplies oxygen to the masks.
  • OFF:
  • The supply valve is closed.

MASK MAN ON pb

The MASK MAN ON pb is a guarded pushbutton.

  • GUARD CLOSED:
    • Normal position.
    • If the cabin altitude is above 13 800 ft, the masks drop automatically.
  • GUARD OPEN:
    • When pushbutton is pressed the masks will drop.

PAX SYS ON LIGHT

  • SYS ON:
    • Oxygen flows toward the passenger masks.
    • The light remains on, until the RESET pb on the OXYGEN maintenance panel is pressed.

Back to Overhead